• New
PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched
search
  • PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched
  • PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched
  • PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched
  • PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched
PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched
PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched

PDU 24 Outlets PX4-5884-E7 Outlet Metered and Switched

PDU, 24 Outlets PX4-5884-E7, Outlet Metered and Switched, (12) C13, (12) Cx, with locking

Please contact us if you are interested

 

Energy Metering: Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

Metering Accuracy: Class 0.5 meter

Metering per input line: Yes

Metering per Branch Circuit Breaker: Yes

Metering per Output Receptacle: Yes

Remote Outlet Switching: Yes

Power Quality Monitoring: Voltage and Current Harmonic Distortion; Distortion Power Factor; Voltage Dip and Voltage Swell; Neutral Current, Current Inrush, Crest Factor

Outlet Power Distribution: Alternating Branch

Replaceable Controller: Yes, hot-swappable

Environmental Sensor Ready: Yes

Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Dust/Particle, Water Leak, Proximity/Motion, Vibration, Dry Contact, and Contact Closure.

PDU Linking: Link up to 8 PDUs where the Primary PDU has knowledge and power information from the attached Expansion PDUs. Redundant power from the first expansion unit ensures uptime even if the Primary PDU loses power.

Cascading: Physically cascade 32 PDUs under one ethernet port or 16 PDUs with USB using bridging mode, or additionally, save IP addresses using a single IP address with port forwarding.

Linking: Yes, a maximum of 8 PDUs can be linked using the PDU Link Port; PDU 1 is defined as the Primary PDU and can link up to 7 additional PDUs, called Link PDUs, totaling 8 PDUs.

Networking: (10/100/1000 Base T) Ethernet, Secondary redundant (10/100/1000 Base T) Ethernet. Optional WiFi (802.11 a/b/g/n).

Remote Management: HTTP(s); SSH (CLI); Telnet; RS-232 (Serial); SNMP version v2/v3; SMTP; JSON-RPC API; MODBUS-TCP; Redfish API

Onboard Display: Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation.

 

Specifications

Input

Input Plug: NEMA L6-30P

Nominal Voltage: 208V

Maximum Input Current: 30A

Rated Input Current: 24A

Power Capacity: 5kVA

Cord Length: 3m

 

Output

Receptacles (Output Connections): (12) C13, (12) Cx

Overload Protection: 2

 

Physical

Dimensions (WxDxH): 56mm x 65mm x 1780mm

Unit Weight: 5.4 kg

Shipping Weight: 7.6 kg

Mounting: G4-HOLDER-FOR-ZU

 

Environmental

Operating Temperature/Environment: 60 C

Operating Relative Humidity: 85%

Operating Elevation: 0-10000ft

 

Conformance

Regulatory Approvals: UL

Raritan
PX4-5884-E7

Data sheet

Phase
1
Volt
208
Ampère
30
Number of outlets
24
Type outlets
C13, Cx
kVA
5
Type
Outlet Metered and Switched
Form
0U
Lockable
Yes
Cord length
3

You might also like